  Power Electronics

 
     
 
Uninterruptible Power Supply (UPS)
 
 
 
  Helios - HE Online UPS Series - 5 KM to 200 KVA  
   
 
 
     An ONLINE UPS basic design ensures increased reliability by supplying constant, tightly regulated - voltage to the load.
 
 
 
     Helios offers an online, double conversion UPS system. Helios online UPS system is designed to handle wide input range voltage deviations without causing the battery system to take over the inverter load. This reduces the UPS systems reliance on its battery bank thereby increasing the life of the same.
 
 
 
     Introduction of IGBT - based PMW technology reduces harmonic distortions and increases crest factor tolerance and dynamic stability. IGBT based PMW inverter delivers full rated power at temperatures as high as 45 degree centigrade.
 
 
 
Constant current & constant Voltage technology ensures uniform charging of the battery
 
 
 
Flexibility to use various types of batteries like LAT (Lead Acid Tubular), LAP (Lead Acid Plante), SMF (Sealed Maintenance Free), Ni-cd (Nickel - Cadmium)
 
 
 
Standard communication Interface (Optional).
 
     
     
  Helios - XL Series - Upto 150 KVA
   
  Rectifier    
 
     Which converts AC voltage of the mains into DC voltage supply for the inverter and battery. Its adequate sizing allows the recharge of long array of batteries while simultaneously supplying the inverter. In order to avoid in rush current on mains, the electronic regulation assures a smooth power walk - in .
 
 
 
Battery
 
 
     Provides the energy for the back up in the event of a power failure or if the mains supply is out of tolerance " Sealed lead" battery technology is usually proposed, which uses gas recombination. This allows the integration of the battery in the UPS itself or in a matching cabinet and it limits the maintenance.
 
 
 
Inverter
 
 
     Which provides AC voltage of high quality to the load by transforming the DC voltage from the rectifier or battery. IGBT power transistor and PMW technology is used with high frequency switching. This gives it exceptional dynamic performance both for step loads and for supplying non-linear loads due to switch mode computer power supplies. The built-in transformer ensures the galvanic isolation bet'n DC voltage and the load.

 
 
Static BY PASS
     Which enables the load to be supplied directly by the mains, without interruption, in the event of excessive overload or breakdown of the UPS.
 
  Manual BY PASS
    To provide continuity of supply to the load during maintenance of the UPS.
 
   
  0.5 KVA-120 KVA
Technical specification
Voltage :
140V- 270V
340V - 480V
Frequency:
50 Hz 5%
Converter :
Full bridge SCR Controlled
Protection:
HRC Fuses, Soft Start for 18 sec. Power walk-in DCV Hightrip
Battery Voltage:
48V to 384V DC (accordingly input tolerance varies)
OUTPUT Voltage:
230V AC Single Phase
415V AC Three Phase
Voltage Stability:
1:1 % for liP - DC Voltage & OIP Load Variation
Frequency:
50 Hz :I: 0.01 %
Waveform:
Sinusoida
Switching Frequency:
12-20 KHz
Harmonic Distortion:
<3%
Load Power Factor:
0.7 Lag to unity
Inverter Efficiency:
92%
Duty :
Continuous
Power Device:
IGBT (Insulated Gate Bipolar Transistor)IPM (Intelligent Power Module
Over Load:
125% for 15 minitues 150% for 1 minute
Protection:
c
Crest Factor Transient :
3:1 Within 20 mSec (1 Cycle)
Recovery Audible :
<45dB
Noise Ambient Temp Cooling:
0-45 Deg.C
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SPECIAL FEATURES
 
1 Phase Input Range - 140V - 270V * 3 Phase Input Range -     340V - 480V * Power Device IGBT, IPM
RF filter in input & Output.
Inverter controlled by micro controller
Soft - Start for Inverter and charger.. High frequency PWM     Technique in Inverter
Converter: Six pulse fully controlled Bridge, Rectifier to improve Converter efficiency
4micro Controller based control circuits
very High Efficiency, very low energy loss.
Reliability built in, very Long MTBF.
Multiple options of various configurations
Output Virtual Short circuit protection
 
ENVIRONMENT
Ambient Temperature Range
 
Operating:
0° to 40°C
(max 40° for 8 hours)**
Storage:
-250C to 70°C
Relative Humidity:
90% non-condensing type at 20°C
Max. Operating:
100 Meters from MSL
Altitude without derating
Acoustic Noiseat 1 Metre from
Panel - Front
57 to 73 dBA(depending on KVA rating)
CABLE ENTRY
Bottom
CABINET FINISH
Powder - Coated
Front, Rear &
Top Cover
Structured WhiteEpoxy Polyester
Front, Door & Side Cover
Structured Black Epoxy Polyester
METERING
Standard Optional
Output Voltage Input Voltage
Battery Voltage Input Current
Output Current Output Frequency Battery Current
INDICATIONS
Mains On, Charger ON, Inverter On, battery Low, Over Load, Sequence Failure, Charger Trip, Inverter Trip
CONFIGURATION
        Stand Alone Type True online UPS System

        Partial Redundant UPS SystemDual Hot standby Redundant type UPS SystemDual Redundant parallel            Load

        Sharing UPS System it. Multiple Redundant Load Sharing UPS SystemOPTIONAL
FEATURES :
        Static Bypass System

        Isolation Transformer and Servo Stabilizer in bypass Additional Indications andAlarms.Colour Wheels           Remote Panel
PHYSICAL DIMENSIONS
WIDTH
DEPTH
HEIGHT
1.0KVA, 2.0KA, 3.0KVA (1-1)
280
540
520
4.0KVA, 5.0KVA, 6.0KVA      
7.5KVA, 10.0KVA, (I-l$)
330
620
580
12.5KVA, 15.0KVA, 20.0 KVA, 25.0 KVA
425
800
800
(3 - 1)   Above 25.0KVA on request
   
         
 
 